Energy Performance Certificate

11, Neville Road, Sutton, NR12 9RP

EPC Report

Energy rating

Current: 44 E | Potential: 107 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 107 A Potential: 107 A

Environmental impact (CO₂)

Current: 38 | Potential: 99
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 99 Potential: 99
Field Value
LMK KEY 2178-0050-7236-3075-2930
ADDRESS1 11, Neville Road
ADDRESS2 Sutton
ADDRESS3
POSTCODE NR12 9RP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 107
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-06-23
LOCAL AUTHORITY E07000147
CONSTITUENCY E14001396
COUNTY
LODGEMENT DATE 2015-06-29
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 99
ENERGY CONSUMPTION CURRENT 294
ENERGY CONSUMPTION POTENTIAL -77
CO2 EMISSIONS CURRENT 6.0
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL -0.1
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 869
HEATING COST POTENTIAL 406
HOT WATER COST CURRENT 235
HOT WATER COST POTENTIAL 94
TOTAL FLOOR AREA 79
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.368
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Neville Road, Sutton
LOCAL AUTHORITY LABEL North Norfolk
CONSTITUENCY LABEL North Norfolk
POSTTOWN NORWICH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-06-29 22:23:34
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100090879082
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew