Energy Performance Certificate

FLAT 6, 40 KNIGHTS WAY, RG4 8RH

EPC Report

Energy rating

Current: 43 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 49 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 63 Potential: 63
Field Value
LMK KEY 2175-1191-4130-4117-3771
ADDRESS1 FLAT 6
ADDRESS2 40 KNIGHTS WAY
ADDRESS3
POSTCODE RG4 8RH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2021-06-17
LOCAL AUTHORITY E06000038
CONSTITUENCY E14001438
COUNTY
LODGEMENT DATE 2021-06-17
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 409
ENERGY CONSUMPTION POTENTIAL 289
CO2 EMISSIONS CURRENT 3.5
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 823
HEATING COST POTENTIAL 275
HOT WATER COST CURRENT 365
HOT WATER COST POTENTIAL 164
TOTAL FLOOR AREA 51
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.11
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS FLAT 6, 40 KNIGHTS WAY
LOCAL AUTHORITY LABEL Reading
CONSTITUENCY LABEL Reading Central
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-06-17 18:21:42
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 310000731
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew