Energy Performance Certificate

66 Cowick Road, SW17 8PF

EPC Report

Energy rating

Current: 63 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 45 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 66 Potential: 66
Field Value
LMK KEY 2171-3051-2205-4635-4204
ADDRESS1 66 Cowick Road
ADDRESS2
ADDRESS3
POSTCODE SW17 8PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-05-23
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001550
COUNTY
LODGEMENT DATE 2025-06-11
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 480
ENERGY CONSUMPTION POTENTIAL 287
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 81
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 51
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 527
HEATING COST POTENTIAL 248
HOT WATER COST CURRENT 362
HOT WATER COST POTENTIAL 213
TOTAL FLOOR AREA 39
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.59
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 66 Cowick Road
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Tooting
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-06-11 13:30:44
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 3
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100022629570
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew