Energy Performance Certificate

11 Oakwood Court, Marton-In-Cleveland, TS7 8TA

EPC Report

Energy rating

Current: 72 C | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 77 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 79 Potential: 79
Field Value
LMK KEY 2170-8460-7150-3090-8125
ADDRESS1 11 Oakwood Court
ADDRESS2 Marton-In-Cleveland
ADDRESS3
POSTCODE TS7 8TA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2025-10-28
LOCAL AUTHORITY E06000002
CONSTITUENCY E14001368
COUNTY
LODGEMENT DATE 2025-10-28
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 236
ENERGY CONSUMPTION POTENTIAL 217
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 24
LIGHTING COST POTENTIAL 24
HEATING COST CURRENT 259
HEATING COST POTENTIAL 259
HOT WATER COST CURRENT 154
HOT WATER COST POTENTIAL 131
TOTAL FLOOR AREA 31
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Flat rate charging, TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical extract, decentralised (MEV dc)
ADDRESS 11 Oakwood Court, Marton-In-Cleveland
LOCAL AUTHORITY LABEL Middlesbrough
CONSTITUENCY LABEL Middlesbrough South and East Cleveland
POSTTOWN MIDDLESBROUGH
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2025-10-28 12:22:41
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100110677430
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000001
Address display
Nation ew