Energy Performance Certificate

19 George Elliott Close, UTTOXETER, ST14 8SL

EPC Report

Energy rating

Current: 65 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 60 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 77 Potential: 77
Field Value
LMK KEY 2170-6067-8020-1104-4391
ADDRESS1 19 George Elliott Close
ADDRESS2
ADDRESS3 UTTOXETER
POSTCODE ST14 8SL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-03-14
LOCAL AUTHORITY E07000193
CONSTITUENCY E14001143
COUNTY
LODGEMENT DATE 2022-03-15
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 261
ENERGY CONSUMPTION POTENTIAL 153
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 144
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 644
HEATING COST POTENTIAL 582
HOT WATER COST CURRENT 82
HOT WATER COST POTENTIAL 57
TOTAL FLOOR AREA 87
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19 George Elliott Close, UTTOXETER
LOCAL AUTHORITY LABEL East Staffordshire
CONSTITUENCY LABEL Burton and Uttoxeter
POSTTOWN
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2022-03-15 11:56:26
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100031678014
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display
Nation ew