Energy Performance Certificate

3 Providence Place, CO1 2LN

EPC Report

Energy rating

Current: 50 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 45 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 82 Potential: 82
Field Value
LMK KEY 2146-0232-1017-9015-4111
ADDRESS1 3 Providence Place
ADDRESS2
ADDRESS3
POSTCODE CO1 2LN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-04-26
LOCAL AUTHORITY E07000071
CONSTITUENCY E14001176
COUNTY
LODGEMENT DATE 2022-04-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 406
ENERGY CONSUMPTION POTENTIAL 103
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 690
HEATING COST POTENTIAL 404
HOT WATER COST CURRENT 79
HOT WATER COST POTENTIAL 55
TOTAL FLOOR AREA 52
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.14
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 Providence Place
LOCAL AUTHORITY LABEL Colchester
CONSTITUENCY LABEL Colchester
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-04-27 15:22:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10004946063
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew