Energy Performance Certificate

Flat 6, 39 Valley Road, SW16 2XL

EPC Report

Energy rating

Current: 75 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 94 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 Current: 94 94 Potential: 94
Field Value
LMK KEY 2145-0633-7755-2008-8925
ADDRESS1 Flat 6, 39 Valley Road
ADDRESS2
ADDRESS3
POSTCODE SW16 2XL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-07-28
LOCAL AUTHORITY E09000022
CONSTITUENCY E14001527
COUNTY
LODGEMENT DATE 2025-08-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 94
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 145
ENERGY CONSUMPTION POTENTIAL 146
CO2 EMISSIONS CURRENT 0.3
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 23
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 276
HEATING COST POTENTIAL 177
HOT WATER COST CURRENT 235
HOT WATER COST POTENTIAL 270
TOTAL FLOOR AREA 20
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, with additional insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.3
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 6, 39 Valley Road
LOCAL AUTHORITY LABEL Lambeth
CONSTITUENCY LABEL Streatham and Croydon North
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-08-14 00:37:38
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100021907103
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew