Energy Performance Certificate

63 Lynhurst Avenue, Sticklepath, EX31 2HY

EPC Report

Energy rating

Current: 61 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 53 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 69 Potential: 69
Field Value
LMK KEY 2140-4825-9020-2004-9495
ADDRESS1 63 Lynhurst Avenue
ADDRESS2 Sticklepath
ADDRESS3
POSTCODE EX31 2HY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-05-11
LOCAL AUTHORITY E07000043
CONSTITUENCY E14001387
COUNTY
LODGEMENT DATE 2022-05-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 266
ENERGY CONSUMPTION POTENTIAL 159
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 701
HEATING COST POTENTIAL 625
HOT WATER COST CURRENT 98
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 63 Lynhurst Avenue, Sticklepath
LOCAL AUTHORITY LABEL North Devon
CONSTITUENCY LABEL North Devon
POSTTOWN BARNSTAPLE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2022-05-12 07:51:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100040249824
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew