Energy Performance Certificate

1 MEADOWBROOK CLOSE, CROSS LANES, WREXHAM, LL13 0UX

EPC Report

Energy rating

Current: 70 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 65 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 80 Potential: 80
Field Value
LMK KEY 2139-6524-0000-0707-5296
ADDRESS1 1 MEADOWBROOK CLOSE
ADDRESS2 CROSS LANES
ADDRESS3 WREXHAM
POSTCODE LL13 0UX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-04-13
LOCAL AUTHORITY W06000006
CONSTITUENCY W07000111
COUNTY
LODGEMENT DATE 2021-04-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 190
ENERGY CONSUMPTION POTENTIAL 104
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 681
HEATING COST POTENTIAL 564
HOT WATER COST CURRENT 135
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 125
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 MEADOWBROOK CLOSE, CROSS LANES, WREXHAM
LOCAL AUTHORITY LABEL Wrexham
CONSTITUENCY LABEL Wrexham
POSTTOWN WREXHAM
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2021-04-15 08:34:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 100100887937
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew