Energy Performance Certificate
494 TRELAWNEY AVENUE, SL3 7TS
Energy rating
Current: 78 C | Potential: 78 C
Environmental impact (CO₂)
Current: 80
| Potential: 80
| Field | Value |
|---|---|
| LMK KEY | 2139-4226-6000-0138-7292 |
| ADDRESS1 | 494 TRELAWNEY AVENUE |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | SL3 7TS |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 78 |
| POTENTIAL ENERGY EFFICIENCY | 78 |
| PROPERTY TYPE | Flat |
| BUILT FORM | End-Terrace |
| INSPECTION DATE | 2021-06-18 |
| LOCAL AUTHORITY | E06000039 |
| CONSTITUENCY | E14001588 |
| COUNTY | — |
| LODGEMENT DATE | 2021-06-18 |
| TRANSACTION TYPE | Rental |
| ENVIRONMENT IMPACT CURRENT | 80 |
| ENVIRONMENT IMPACT POTENTIAL | 80 |
| ENERGY CONSUMPTION CURRENT | 156 |
| ENERGY CONSUMPTION POTENTIAL | 156 |
| CO2 EMISSIONS CURRENT | 1.3 |
| CO2 EMISS CURR PER FLOOR AREA | 28 |
| CO2 EMISSIONS POTENTIAL | 1.3 |
| LIGHTING COST CURRENT | 48 |
| LIGHTING COST POTENTIAL | 48 |
| HEATING COST CURRENT | 193 |
| HEATING COST POTENTIAL | 193 |
| HOT WATER COST CURRENT | 101 |
| HOT WATER COST POTENTIAL | 101 |
| TOTAL FLOOR AREA | 47 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | 2 |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Flat rate charging, TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 2 |
| NUMBER HEATED ROOMS | 2 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Community scheme |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Community scheme |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Flat rate charging, TRVs |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | unheated corridor |
| UNHEATED CORRIDOR LENGTH | 4.43 |
| FLOOR HEIGHT | 2.38 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 494 TRELAWNEY AVENUE |
| LOCAL AUTHORITY LABEL | Slough |
| CONSTITUENCY LABEL | Windsor |
| POSTTOWN | SLOUGH |
| CONSTRUCTION AGE BAND | England and Wales: 1976-1982 |
| LODGEMENT DATETIME | 2021-06-18 11:19:54 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| UPRN | 100080340065 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2021.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |