Energy Performance Certificate

41, Pendle Drive, Whalley, BB7 9JT

EPC Report

Energy rating

Current: 54 E | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 50 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 78 Potential: 78
Field Value
LMK KEY 2138-9921-6299-4357-0990
ADDRESS1 41, Pendle Drive
ADDRESS2 Whalley
ADDRESS3
POSTCODE BB7 9JT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-11-27
LOCAL AUTHORITY E07000124
CONSTITUENCY E14001443
COUNTY
LODGEMENT DATE 2013-11-27
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 242
ENERGY CONSUMPTION POTENTIAL 103
CO2 EMISSIONS CURRENT 8.7
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 109
HEATING COST CURRENT 1554
HEATING COST POTENTIAL 820
HOT WATER COST CURRENT 195
HOT WATER COST POTENTIAL 130
TOTAL FLOOR AREA 188
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 76
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 76% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.53
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 41, Pendle Drive, Whalley
LOCAL AUTHORITY LABEL Ribble Valley
CONSTITUENCY LABEL Ribble Valley
POSTTOWN CLITHEROE
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2013-11-27 17:58:28
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 33
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 10070402853
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew