Energy Performance Certificate

89, Kingsway, DN15 7ER

EPC Report

Energy rating

Current: 51 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 42 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 65 Potential: 65
Field Value
LMK KEY 2138-6059-7232-5668-5914
ADDRESS1 89, Kingsway
ADDRESS2
ADDRESS3
POSTCODE DN15 7ER
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-02-27
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001462
COUNTY
LODGEMENT DATE 2018-03-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 345
ENERGY CONSUMPTION POTENTIAL 192
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 4.7
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 1468
HEATING COST POTENTIAL 985
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 136
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 39
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 39% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 89, Kingsway
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Scunthorpe
POSTTOWN SCUNTHORPE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-03-19 10:59:20
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100050210778
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000003
Address display
Nation ew