Energy Performance Certificate

1 Vidlers Court, The Strand, TN31 7DB

EPC Report

Energy rating

Current: 29 F | Potential: 58 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 58 D Potential: 58 D

Environmental impact (CO₂)

Current: 28 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 49 Potential: 49
Field Value
LMK KEY 2138-5904-7249-1267-9930
ADDRESS1 1 Vidlers Court
ADDRESS2 The Strand
ADDRESS3
POSTCODE TN31 7DB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 58
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2013-11-27
LOCAL AUTHORITY E07000064
CONSTITUENCY E14001274
COUNTY
LODGEMENT DATE 2013-11-27
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 591
ENERGY CONSUMPTION POTENTIAL 347
CO2 EMISSIONS CURRENT 6.5
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 1191
HEATING COST POTENTIAL 602
HOT WATER COST CURRENT 118
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 62
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 60
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters, Room heaters, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 11.46
FLOOR HEIGHT 3.07
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Vidlers Court, The Strand
LOCAL AUTHORITY LABEL Rother
CONSTITUENCY LABEL Hastings and Rye
POSTTOWN RYE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-11-27 16:01:40
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 200002904617
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew