Energy Performance Certificate

7 LAKESIDE PARK, WF6 1WN

EPC Report

Energy rating

Current: 74 C | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 69 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 69 Potential: 69
Field Value
LMK KEY 2136-7601-7603-7806-2158
ADDRESS1 7 LAKESIDE PARK
ADDRESS2
ADDRESS3
POSTCODE WF6 1WN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-05-24
LOCAL AUTHORITY E08000036
CONSTITUENCY E14001383
COUNTY
LODGEMENT DATE 2021-05-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 250
ENERGY CONSUMPTION POTENTIAL 250
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 315
HEATING COST POTENTIAL 315
HOT WATER COST CURRENT 225
HOT WATER COST POTENTIAL 225
TOTAL FLOOR AREA 53
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.18
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7 LAKESIDE PARK
LOCAL AUTHORITY LABEL Wakefield
CONSTITUENCY LABEL Normanton and Hemsworth
POSTTOWN NORMANTON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2021-05-27 18:53:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 63153827
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000003
Address display
Nation ew