Energy Performance Certificate

34 Seafield Drive, CH45 0LW

EPC Report

Energy rating

Current: 35 F | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 27 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 65 Potential: 65
Field Value
LMK KEY 2135-1950-1560-0124-7177
ADDRESS1 34 Seafield Drive
ADDRESS2
ADDRESS3
POSTCODE CH45 0LW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-12-09
LOCAL AUTHORITY E08000015
CONSTITUENCY E14001561
COUNTY
LODGEMENT DATE 2022-12-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 418
ENERGY CONSUMPTION POTENTIAL 161
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 197
LIGHTING COST POTENTIAL 125
HEATING COST CURRENT 2494
HEATING COST POTENTIAL 1124
HOT WATER COST CURRENT 123
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 202
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 80
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 43
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 43% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.17
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34 Seafield Drive
LOCAL AUTHORITY LABEL Wirral
CONSTITUENCY LABEL Wallasey
POSTTOWN WALLASEY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-12-09 11:28:56
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 42103647
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000002
Address display
Nation ew