Energy Performance Certificate

171, Maltravers Road, S2 5AF

EPC Report

Energy rating

Current: 49 E | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 42 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 84 Potential: 84
Field Value
LMK KEY 2128-5044-6202-8986-8944
ADDRESS1 171, Maltravers Road
ADDRESS2
ADDRESS3
POSTCODE S2 5AF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-02-22
LOCAL AUTHORITY E08000039
CONSTITUENCY E14001469
COUNTY
LODGEMENT DATE 2016-02-22
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 419
ENERGY CONSUMPTION POTENTIAL 105
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 88
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 752
HEATING COST POTENTIAL 433
HOT WATER COST CURRENT 308
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 69
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 13
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 13% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 171, Maltravers Road
LOCAL AUTHORITY LABEL Sheffield
CONSTITUENCY LABEL Sheffield Heeley
POSTTOWN SHEFFIELD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-02-22 18:21:46
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100051022567
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew