Energy Performance Certificate

Highview, Claycastle, TA18 7PE

EPC Report

Energy rating

Current: 28 F | Potential: 47 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 F Current: 28 F 47 E Potential: 47 E

Environmental impact (CO₂)

Current: 35 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 50 Potential: 50
Field Value
LMK KEY 2122-2136-4101-4411-7191
ADDRESS1 Highview
ADDRESS2 Claycastle
ADDRESS3
POSTCODE TA18 7PE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 28
POTENTIAL ENERGY EFFICIENCY 47
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-04-28
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001603
COUNTY
LODGEMENT DATE 2024-04-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 392
ENERGY CONSUMPTION POTENTIAL 255
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 5.6
LIGHTING COST CURRENT 143
LIGHTING COST POTENTIAL 143
HEATING COST CURRENT 3619
HEATING COST POTENTIAL 3222
HOT WATER COST CURRENT 1037
HOT WATER COST POTENTIAL 357
TOTAL FLOOR AREA 122
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Highview, Claycastle
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Yeovil
POSTTOWN CREWKERNE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-04-29 07:22:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 30048070
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew