Energy Performance Certificate

1 Chestnut Avenue, Welburn, YO60 7EH

EPC Report

Energy rating

Current: 57 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 51 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 66 Potential: 66
Field Value
LMK KEY 2121-9271-1655-3322-2144
ADDRESS1 1 Chestnut Avenue
ADDRESS2 Welburn
ADDRESS3
POSTCODE YO60 7EH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-04-12
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001544
COUNTY
LODGEMENT DATE 2021-10-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 236
ENERGY CONSUMPTION POTENTIAL 146
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 854
HEATING COST POTENTIAL 765
HOT WATER COST CURRENT 160
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Chestnut Avenue, Welburn
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Thirsk and Malton
POSTTOWN York
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-10-21 10:59:19
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100050455805
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000003
Address display
Nation ew