Energy Performance Certificate

4 Park View, Adwick Le Street, DN6 7DP

EPC Report

Energy rating

Current: 77 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 77 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 89 Potential: 89
Field Value
LMK KEY 2121-3111-8223-1380-4112
ADDRESS1 4 Park View
ADDRESS2 Adwick Le Street
ADDRESS3
POSTCODE DN6 7DP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-10-11
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001200
COUNTY
LODGEMENT DATE 2023-04-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 150
ENERGY CONSUMPTION POTENTIAL 69
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 1
LIGHTING COST CURRENT 134
LIGHTING COST POTENTIAL 134
HEATING COST CURRENT 714
HEATING COST POTENTIAL 714
HOT WATER COST CURRENT 256
HOT WATER COST POTENTIAL 172
TOTAL FLOOR AREA 78
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.424
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Park View, Adwick Le Street
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster North
POSTTOWN Doncaster
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2023-04-24 15:11:00
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10006714067
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000003
Address display
Nation ew