Energy Performance Certificate

45 STATION WAY, SG6 3SD

EPC Report

Energy rating

Current: 48 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 43 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 69 Potential: 69
Field Value
LMK KEY 2120-8288-1090-8003-5805
ADDRESS1 45 STATION WAY
ADDRESS2
ADDRESS3
POSTCODE SG6 3SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2021-08-05
LOCAL AUTHORITY E07000099
CONSTITUENCY E14001393
COUNTY
LODGEMENT DATE 2021-08-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 342
ENERGY CONSUMPTION POTENTIAL 169
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 145
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 1344
HEATING COST POTENTIAL 915
HOT WATER COST CURRENT 87
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 110
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 19
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 19% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.68
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 45 STATION WAY
LOCAL AUTHORITY LABEL North Hertfordshire
CONSTITUENCY LABEL North East Hertfordshire
POSTTOWN LETCHWORTH GARDEN CITY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-08-06 08:48:25
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100080821283
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew