Energy Performance Certificate

Hill Crest, Forge Road, Llangynidr, NP8 1LU

EPC Report

Energy rating

Current: 25 F | Potential: 57 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 57 D Potential: 57 D

Environmental impact (CO₂)

Current: 30 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 55 Potential: 55
Field Value
LMK KEY 2120-6230-0140-5095-9071
ADDRESS1 Hill Crest
ADDRESS2 Forge Road
ADDRESS3 Llangynidr
POSTCODE NP8 1LU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 57
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-10-31
LOCAL AUTHORITY W06000023
CONSTITUENCY W07000085
COUNTY
LODGEMENT DATE 2024-11-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 506
ENERGY CONSUMPTION POTENTIAL 273
CO2 EMISSIONS CURRENT 13.6
CO2 EMISS CURR PER FLOOR AREA 82
CO2 EMISSIONS POTENTIAL 7.3
LIGHTING COST CURRENT 220
LIGHTING COST POTENTIAL 220
HEATING COST CURRENT 7987
HEATING COST POTENTIAL 4870
HOT WATER COST CURRENT 513
HOT WATER COST POTENTIAL 287
TOTAL FLOOR AREA 167
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 94
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Hill Crest, Forge Road, Llangynidr
LOCAL AUTHORITY LABEL Powys
CONSTITUENCY LABEL Brecon, Radnor and Cwm Tawe
POSTTOWN CRICKHOWELL
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-11-01 14:05:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 100100320255
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew