Energy Performance Certificate

36 Manor Crescent, Stapleton, LE9 8JQ

EPC Report

Energy rating

Current: 99 A | Potential: 103 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 99 A Current: 99 A 103 A Potential: 103 A

Environmental impact (CO₂)

Current: 96 | Potential: 102
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 96 Current: 96 102 Potential: 102
Field Value
LMK KEY 2120-1854-1050-4002-1325
ADDRESS1 36 Manor Crescent
ADDRESS2 Stapleton
ADDRESS3
POSTCODE LE9 8JQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 99
POTENTIAL ENERGY EFFICIENCY 103
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2025-04-29
LOCAL AUTHORITY E07000132
CONSTITUENCY E14001288
COUNTY
LODGEMENT DATE 2025-04-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 96
ENVIRONMENT IMPACT POTENTIAL 102
ENERGY CONSUMPTION CURRENT 22
ENERGY CONSUMPTION POTENTIAL -14
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 4
CO2 EMISSIONS POTENTIAL -0.2
LIGHTING COST CURRENT 120
LIGHTING COST POTENTIAL 120
HEATING COST CURRENT 629
HEATING COST POTENTIAL 545
HOT WATER COST CURRENT 354
HOT WATER COST POTENTIAL 206
TOTAL FLOOR AREA 100
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 40
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36 Manor Crescent, Stapleton
LOCAL AUTHORITY LABEL Hinckley and Bosworth
CONSTITUENCY LABEL Hinckley and Bosworth
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-04-29 08:00:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100030521842
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000004
Address display
Nation ew