Energy Performance Certificate

1 Ebenezer Cottages, The Tollgate, CV13 0HL

EPC Report

Energy rating

Current: 13 G | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 G Current: 13 G 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 26 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 70 Potential: 70
Field Value
LMK KEY 2118-7115-3127-4397-2015
ADDRESS1 1 Ebenezer Cottages
ADDRESS2 The Tollgate
ADDRESS3
POSTCODE CV13 0HL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 13
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2023-10-19
LOCAL AUTHORITY E07000132
CONSTITUENCY E14001288
COUNTY
LODGEMENT DATE 2023-10-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 709
ENERGY CONSUMPTION POTENTIAL 232
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 120
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 118
LIGHTING COST POTENTIAL 128
HEATING COST CURRENT 4340
HEATING COST POTENTIAL 1112
HOT WATER COST CURRENT 803
HOT WATER COST POTENTIAL 220
TOTAL FLOOR AREA 62
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Ebenezer Cottages, The Tollgate
LOCAL AUTHORITY LABEL Hinckley and Bosworth
CONSTITUENCY LABEL Hinckley and Bosworth
POSTTOWN NUNEATON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-10-19 15:41:09
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10033736505
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000004
Address display