Energy Performance Certificate

7a Myrtle Road, RM3 8XS

EPC Report

Energy rating

Current: 65 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 62 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 74 Potential: 74
Field Value
LMK KEY 2118-6119-7272-6136-4554
ADDRESS1 7a Myrtle Road
ADDRESS2
ADDRESS3
POSTCODE RM3 8XS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-12-09
LOCAL AUTHORITY E09000016
CONSTITUENCY E14001292
COUNTY
LODGEMENT DATE 2025-12-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 218
ENERGY CONSUMPTION POTENTIAL 141
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 99
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 897
HEATING COST POTENTIAL 737
HOT WATER COST CURRENT 341
HOT WATER COST POTENTIAL 216
TOTAL FLOOR AREA 91
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 78
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7a Myrtle Road
LOCAL AUTHORITY LABEL Havering
CONSTITUENCY LABEL Hornchurch and Upminster
POSTTOWN ROMFORD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-12-09 13:56:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100021388416
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew