Energy Performance Certificate

Entwood Farm, Harcombe, DT7 3RN

EPC Report

Energy rating

Current: 37 F | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 35 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 57 Potential: 57
Field Value
LMK KEY 2118-6088-7244-6741-1924
ADDRESS1 Entwood Farm
ADDRESS2 Harcombe
ADDRESS3
POSTCODE DT7 3RN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-04-29
LOCAL AUTHORITY E07000040
CONSTITUENCY E14001291
COUNTY
LODGEMENT DATE 2019-04-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 207
ENERGY CONSUMPTION POTENTIAL 114
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 7.6
LIGHTING COST CURRENT 120
LIGHTING COST POTENTIAL 120
HEATING COST CURRENT 1833
HEATING COST POTENTIAL 1115
HOT WATER COST CURRENT 139
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 231
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and underfloor heating, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 20
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Entwood Farm, Harcombe
LOCAL AUTHORITY LABEL East Devon
CONSTITUENCY LABEL Honiton and Sidmouth
POSTTOWN LYME REGIS
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-04-29 16:00:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 10000244193
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew