Energy Performance Certificate

Guest Room Victoria Court, Victoria Road, Warley, CM14 5EX

EPC Report

Energy rating

Current: 75 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 83 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 84 Potential: 84
Field Value
LMK KEY 2117-3573-2021-1005-9716
ADDRESS1 Guest Room Victoria Court, Victoria Road
ADDRESS2 Warley
ADDRESS3
POSTCODE CM14 5EX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-09-18
LOCAL AUTHORITY E07000068
CONSTITUENCY E14001125
COUNTY
LODGEMENT DATE 2023-11-15
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 474
ENERGY CONSUMPTION POTENTIAL 433
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 84
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 28
LIGHTING COST POTENTIAL 28
HEATING COST CURRENT 164
HEATING COST POTENTIAL 138
HOT WATER COST CURRENT 221
HOT WATER COST POTENTIAL 221
TOTAL FLOOR AREA 8
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH 0
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Guest Room Victoria Court, Victoria Road, Warley
LOCAL AUTHORITY LABEL Brentwood
CONSTITUENCY LABEL Brentwood and Ongar
POSTTOWN Brentwood
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2023-11-15 16:27:56
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100091642477
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew