Energy Performance Certificate

9 Johnson Court, Pollards Close, SS4 1GF

EPC Report

Energy rating

Current: 60 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 53 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 73 Potential: 73
Field Value
LMK KEY 2116-7535-7652-6687-1395
ADDRESS1 9 Johnson Court
ADDRESS2 Pollards Close
ADDRESS3
POSTCODE SS4 1GF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2026-03-16
LOCAL AUTHORITY E07000075
CONSTITUENCY E14001501
COUNTY
LODGEMENT DATE 2026-06-19
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 233
ENERGY CONSUMPTION POTENTIAL 126
CO2 EMISSIONS CURRENT 5.3
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1719
HEATING COST POTENTIAL 980
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 255
TOTAL FLOOR AREA 123
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, limited insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9 Johnson Court, Pollards Close
LOCAL AUTHORITY LABEL Rochford
CONSTITUENCY LABEL Southend East and Rochford
POSTTOWN Rochford
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2026-06-19 14:06:09
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100091263804
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew