Energy Performance Certificate

36 Block 3 Bredon Court, Andrew Road, B63 4TP

EPC Report

Energy rating

Current: 27 F | Potential: 46 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 46 E Potential: 46 E

Environmental impact (CO₂)

Current: 16 | Potential: 24
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 24 Potential: 24
Field Value
LMK KEY 2113-1841-9458-1174-1267
ADDRESS1 36 Block 3 Bredon Court, Andrew Road
ADDRESS2
ADDRESS3
POSTCODE B63 4TP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 46
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2024-03-05
LOCAL AUTHORITY E08000027
CONSTITUENCY E14001261
COUNTY
LODGEMENT DATE 2024-07-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 24
ENERGY CONSUMPTION CURRENT 922
ENERGY CONSUMPTION POTENTIAL 751
CO2 EMISSIONS CURRENT 8.7
CO2 EMISS CURR PER FLOOR AREA 156
CO2 EMISSIONS POTENTIAL 7.1
LIGHTING COST CURRENT 158
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 2588
HEATING COST POTENTIAL 1953
HOT WATER COST CURRENT 503
HOT WATER COST POTENTIAL 289
TOTAL FLOOR AREA 56
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.0
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36 Block 3 Bredon Court, Andrew Road
LOCAL AUTHORITY LABEL Dudley
CONSTITUENCY LABEL Halesowen
POSTTOWN Halesowen
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-07-23 11:27:09
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 90152523
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000005
Address display