Energy Performance Certificate

10 Mallard Way, Hollesley, IP12 3QJ

EPC Report

Energy rating

Current: 52 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 32 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 55 Potential: 55
Field Value
LMK KEY 2113-1157-1919-1371-4111
ADDRESS1 10 Mallard Way
ADDRESS2 Hollesley
ADDRESS3
POSTCODE IP12 3QJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-09-29
LOCAL AUTHORITY E07000244
CONSTITUENCY E14001530
COUNTY
LODGEMENT DATE 2022-09-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 465
ENERGY CONSUMPTION POTENTIAL 254
CO2 EMISSIONS CURRENT 9.4
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 115
LIGHTING COST POTENTIAL 115
HEATING COST CURRENT 1838
HEATING COST POTENTIAL 1150
HOT WATER COST CURRENT 240
HOT WATER COST POTENTIAL 143
TOTAL FLOOR AREA 119
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 94
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 87
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 87% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Mallard Way, Hollesley
LOCAL AUTHORITY LABEL East Suffolk
CONSTITUENCY LABEL Suffolk Coastal
POSTTOWN WOODBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2022-09-29 12:03:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 100091146056
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew