Energy Performance Certificate

3 Senlac Close, CT11 0LR

EPC Report

Energy rating

Current: 57 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 39 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 57 Potential: 57
Field Value
LMK KEY 2112-9034-6512-5112-1573
ADDRESS1 3 Senlac Close
ADDRESS2
ADDRESS3
POSTCODE CT11 0LR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2024-09-25
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001216
COUNTY
LODGEMENT DATE 2024-10-21
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 406
ENERGY CONSUMPTION POTENTIAL 245
CO2 EMISSIONS CURRENT 6
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 146
LIGHTING COST POTENTIAL 146
HEATING COST CURRENT 1537
HEATING COST POTENTIAL 1265
HOT WATER COST CURRENT 549
HOT WATER COST POTENTIAL 295
TOTAL FLOOR AREA 88
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 Senlac Close
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL East Thanet
POSTTOWN RAMSGATE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-10-21 14:15:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100061143391
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew