Energy Performance Certificate

22 Mountreed, Five Ashes, TN20 6LN

EPC Report

Energy rating

Current: 72 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 93 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 93 Current: 93 95 Potential: 95
Field Value
LMK KEY 2112-4206-3261-9122-0179
ADDRESS1 22 Mountreed
ADDRESS2 Five Ashes
ADDRESS3
POSTCODE TN20 6LN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2026-04-14
LOCAL AUTHORITY E07000065
CONSTITUENCY E14001533
COUNTY
LODGEMENT DATE 2026-04-14
TRANSACTION TYPE Re-mortgaging
ENVIRONMENT IMPACT CURRENT 93
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 80
ENERGY CONSUMPTION POTENTIAL 53
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 8
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 800
HEATING COST POTENTIAL 725
HOT WATER COST CURRENT 415
HOT WATER COST POTENTIAL 312
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical extract, decentralised (MEV dc)
ADDRESS 22 Mountreed, Five Ashes
LOCAL AUTHORITY LABEL Wealden
CONSTITUENCY LABEL Sussex Weald
POSTTOWN MAYFIELD
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2026-04-14 16:03:56
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10033403487
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000008
Address display
Nation ew