Energy Performance Certificate

10 Wolmer Close, HA8 8PU

EPC Report

Energy rating

Current: 70 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 67 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 82 Potential: 82
Field Value
LMK KEY 2111-8048-1111-2102-9188
ADDRESS1 10 Wolmer Close
ADDRESS2
ADDRESS3
POSTCODE HA8 8PU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-07-12
LOCAL AUTHORITY E09000003
CONSTITUENCY E14001169
COUNTY
LODGEMENT DATE 2023-07-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 182
ENERGY CONSUMPTION POTENTIAL 89
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 270
LIGHTING COST POTENTIAL 203
HEATING COST CURRENT 1472
HEATING COST POTENTIAL 1181
HOT WATER COST CURRENT 242
HOT WATER COST POTENTIAL 164
TOTAL FLOOR AREA 113
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Wolmer Close
LOCAL AUTHORITY LABEL Barnet
CONSTITUENCY LABEL Chipping Barnet
POSTTOWN EDGWARE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2023-07-14 06:56:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 200127902
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew