Energy Performance Certificate

16 Zenith Avenue, Shinfield, RG2 9FN

EPC Report

Energy rating

Current: 77 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 77 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 89 Potential: 89
Field Value
LMK KEY 2111-2147-0271-3181-0126
ADDRESS1 16 Zenith Avenue
ADDRESS2 Shinfield
ADDRESS3
POSTCODE RG2 9FN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-10-16
LOCAL AUTHORITY E06000041
CONSTITUENCY E14001210
COUNTY
LODGEMENT DATE 2024-09-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 140
ENERGY CONSUMPTION POTENTIAL 49
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 115
LIGHTING COST POTENTIAL 115
HEATING COST CURRENT 497
HEATING COST POTENTIAL 497
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 127
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16 Zenith Avenue, Shinfield
LOCAL AUTHORITY LABEL Wokingham
CONSTITUENCY LABEL Earley and Woodley
POSTTOWN Reading
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2024-09-13 07:07:00
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10032928075
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew