Energy Performance Certificate

7 Nursery Road, TN4 9BY

EPC Report

Energy rating

Current: 3 G | Potential: 57 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 3 G Current: 3 G 57 D Potential: 57 D

Environmental impact (CO₂)

Current: 6 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 6 Current: 6 47 Potential: 47
Field Value
LMK KEY 2111-0123-9508-5587-1732
ADDRESS1 7 Nursery Road
ADDRESS2
ADDRESS3
POSTCODE TN4 9BY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 3
POTENTIAL ENERGY EFFICIENCY 57
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-03-13
LOCAL AUTHORITY E07000116
CONSTITUENCY E14001555
COUNTY
LODGEMENT DATE 2024-03-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 6
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 817
ENERGY CONSUMPTION POTENTIAL 270
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 172
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 138
LIGHTING COST POTENTIAL 138
HEATING COST CURRENT 4746
HEATING COST POTENTIAL 1942
HOT WATER COST CURRENT 635
HOT WATER COST POTENTIAL 304
TOTAL FLOOR AREA 70
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.53
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7 Nursery Road
LOCAL AUTHORITY LABEL Tunbridge Wells
CONSTITUENCY LABEL Tunbridge Wells
POSTTOWN TUNBRIDGE WELLS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-03-13 13:23:13
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100061209318
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew