Energy Performance Certificate

7, Palmerston Street, Bollington, SK10 5PX

EPC Report

Energy rating

Current: 65 D | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 64 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 94 Potential: 94
Field Value
LMK KEY 2108-1040-6263-7290-2280
ADDRESS1 7, Palmerston Street
ADDRESS2 Bollington
ADDRESS3
POSTCODE SK10 5PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-07-20
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001347
COUNTY
LODGEMENT DATE 2020-07-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 324
ENERGY CONSUMPTION POTENTIAL 53
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 36
HEATING COST CURRENT 430
HEATING COST POTENTIAL 285
HOT WATER COST CURRENT 62
HOT WATER COST POTENTIAL 40
TOTAL FLOOR AREA 40
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.27
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Palmerston Street, Bollington
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Macclesfield
POSTTOWN MACCLESFIELD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-07-20 17:51:39
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100010154286
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew