Energy Performance Certificate

32 Repps Road, Martham, NR29 4QT

EPC Report

Energy rating

Current: 75 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 76 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 88 Potential: 88
Field Value
LMK KEY 2100-0575-0122-8400-3143
ADDRESS1 32 Repps Road
ADDRESS2 Martham
ADDRESS3
POSTCODE NR29 4QT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-09-03
LOCAL AUTHORITY E07000145
CONSTITUENCY E14001256
COUNTY
LODGEMENT DATE 2024-09-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 117
ENERGY CONSUMPTION POTENTIAL 54
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 200
LIGHTING COST POTENTIAL 200
HEATING COST CURRENT 2456
HEATING COST POTENTIAL 1569
HOT WATER COST CURRENT 415
HOT WATER COST POTENTIAL 241
TOTAL FLOOR AREA 195
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 85
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 85% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 25
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32 Repps Road, Martham
LOCAL AUTHORITY LABEL Great Yarmouth
CONSTITUENCY LABEL Great Yarmouth
POSTTOWN GREAT YARMOUTH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-09-03 17:35:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 10023461376
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display
Nation ew