Energy Performance Certificate

33 High Mount, Donnington, TF2 7NL

EPC Report

Energy rating

Current: 64 D | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 63 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 93 Potential: 93
Field Value
LMK KEY 2095-3041-7208-3574-1200
ADDRESS1 33 High Mount
ADDRESS2 Donnington
ADDRESS3
POSTCODE TF2 7NL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE Bungalow
BUILT FORM End-Terrace
INSPECTION DATE 2024-08-21
LOCAL AUTHORITY E06000020
CONSTITUENCY E14001543
COUNTY
LODGEMENT DATE 2024-08-21
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 351
ENERGY CONSUMPTION POTENTIAL 62
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 704
HEATING COST POTENTIAL 463
HOT WATER COST CURRENT 146
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 36
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33 High Mount, Donnington
LOCAL AUTHORITY LABEL Telford and Wrekin
CONSTITUENCY LABEL The Wrekin
POSTTOWN TELFORD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-08-21 15:52:08
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 452040315
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000005
Address display
Nation ew