Energy Performance Certificate

13, Brazier Way, Cross Houses, SY5 6LR

EPC Report

Energy rating

Current: 85 B | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 87 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 Current: 87 95 Potential: 95
Field Value
LMK KEY 2090-3968-0732-3090-3203
ADDRESS1 13
ADDRESS2 Brazier Way
ADDRESS3 Cross Houses
POSTCODE SY5 6LR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-12-16
LOCAL AUTHORITY E06000051
CONSTITUENCY E14001493
COUNTY
LODGEMENT DATE 2020-12-16
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 87
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 78
ENERGY CONSUMPTION POTENTIAL 28
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 13
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 93
HEATING COST CURRENT 342
HEATING COST POTENTIAL 343
HOT WATER COST CURRENT 211
HOT WATER COST POTENTIAL 126
TOTAL FLOOR AREA 135
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.13 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.30 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.10 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 13, Brazier Way, Cross Houses
LOCAL AUTHORITY LABEL Shropshire
CONSTITUENCY LABEL South Shropshire
POSTTOWN Shrewsbury
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2020-12-16 17:25:45
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 10093749218
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2020.csv
COUNTRY England
REGION E12000005
Address display
Nation ew