Energy Performance Certificate

9, Leah Close, Marston Green, B37 7JD

EPC Report

Energy rating

Current: 78 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 79 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 80 Potential: 80
Field Value
LMK KEY 2088-0018-7332-0357-5960
ADDRESS1 9, Leah Close
ADDRESS2 Marston Green
ADDRESS3
POSTCODE B37 7JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-02-28
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001358
COUNTY
LODGEMENT DATE 2013-02-28
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 112
ENERGY CONSUMPTION POTENTIAL 106
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 425
HEATING COST POTENTIAL 431
HOT WATER COST CURRENT 94
HOT WATER COST POTENTIAL 94
TOTAL FLOOR AREA 123
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 31
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.20 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.32 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.13 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 31% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 9, Leah Close, Marston Green
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Meriden and Solihull East
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND 2011
LODGEMENT DATETIME 2013-02-28 13:24:20
TENURE
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10023648117
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew