Energy Performance Certificate

2 RUSHENDON FURLONG, PITSTONE, LU7 9QX

EPC Report

Energy rating

Current: 23 F | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 8 | Potential: 37
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 8 Current: 8 37 Potential: 37
Field Value
LMK KEY 2075-6821-1182-8151-0086
ADDRESS1 2 RUSHENDON FURLONG
ADDRESS2 PITSTONE
ADDRESS3
POSTCODE LU7 9QX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-01-07
LOCAL AUTHORITY E06000060
CONSTITUENCY E14001071
COUNTY
LODGEMENT DATE 2021-01-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 8
ENVIRONMENT IMPACT POTENTIAL 37
ENERGY CONSUMPTION CURRENT 872
ENERGY CONSUMPTION POTENTIAL 425
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 147
CO2 EMISSIONS POTENTIAL 7.1
LIGHTING COST CURRENT 169
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 2627
HEATING COST POTENTIAL 1369
HOT WATER COST CURRENT 235
HOT WATER COST POTENTIAL 149
TOTAL FLOOR AREA 98
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 RUSHENDON FURLONG, PITSTONE
LOCAL AUTHORITY LABEL Buckinghamshire
CONSTITUENCY LABEL Aylesbury
POSTTOWN PITSTONE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-01-07 14:54:14
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 766273237
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew