Energy Performance Certificate

41 Muttonshire Hill, Gamston, DN22 0QH

EPC Report

Energy rating

Current: 26 F | Potential: 47 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 F Current: 26 F 47 E Potential: 47 E

Environmental impact (CO₂)

Current: 46 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 65 Potential: 65
Field Value
LMK KEY 2075-0060-6549-1596-8505
ADDRESS1 41 Muttonshire Hill
ADDRESS2 Gamston
ADDRESS3
POSTCODE DN22 0QH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 26
POTENTIAL ENERGY EFFICIENCY 47
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-10-08
LOCAL AUTHORITY E07000171
CONSTITUENCY E14001375
COUNTY
LODGEMENT DATE 2024-10-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 293
ENERGY CONSUMPTION POTENTIAL 155
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 97
HEATING COST CURRENT 1687
HEATING COST POTENTIAL 1461
HOT WATER COST CURRENT 309
HOT WATER COST POTENTIAL 194
TOTAL FLOOR AREA 58
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 60
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, anthracite
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL bottled LPG
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 41 Muttonshire Hill, Gamston
LOCAL AUTHORITY LABEL Bassetlaw
CONSTITUENCY LABEL Newark
POSTTOWN RETFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-10-08 15:17:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100031274735
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000004
Address display
Nation ew