Energy Performance Certificate

23A FORREST CLOSE, SOUTH WOODHAM FERRERS, CHELMSFORD, CM3 5NR

EPC Report

Energy rating

Current: 77 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 78 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 88 Potential: 88
Field Value
LMK KEY 2071-2222-2000-9390-2101
ADDRESS1 23A FORREST CLOSE
ADDRESS2 SOUTH WOODHAM FERRERS
ADDRESS3 CHELMSFORD
POSTCODE CM3 5NR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-12-02
LOCAL AUTHORITY E07000070
CONSTITUENCY E14001351
COUNTY
LODGEMENT DATE 2020-12-02
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 126
ENERGY CONSUMPTION POTENTIAL 59
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 416
HEATING COST POTENTIAL 416
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 103
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 96
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 96% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23A FORREST CLOSE, SOUTH WOODHAM FERRERS, CHELMSFORD
LOCAL AUTHORITY LABEL Chelmsford
CONSTITUENCY LABEL Maldon
POSTTOWN CHELMSFORD
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2020-12-02 15:13:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 24
LOW ENERGY FIXED LIGHT COUNT 23
UPRN 10013272290
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000006
Address display
Nation ew