Energy Performance Certificate

4 Woodland Walk, GU12 4FE

EPC Report

Energy rating

Current: 75 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 76 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 78 Potential: 78
Field Value
LMK KEY 2071-1374-3060-7804-0075
ADDRESS1 4 Woodland Walk
ADDRESS2
ADDRESS3
POSTCODE GU12 4FE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2026-04-30
LOCAL AUTHORITY E07000092
CONSTITUENCY E14001063
COUNTY
LODGEMENT DATE 2026-04-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 125
ENERGY CONSUMPTION POTENTIAL 106
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 227
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 796
HEATING COST POTENTIAL 818
HOT WATER COST CURRENT 259
HOT WATER COST POTENTIAL 258
TOTAL FLOOR AREA 124
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.375
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Woodland Walk
LOCAL AUTHORITY LABEL Rushmoor
CONSTITUENCY LABEL Aldershot
POSTTOWN ALDERSHOT
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2026-04-30 17:30:35
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 39
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10008773374
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000008
Address display
Nation ew