Energy Performance Certificate

228 QUEENS ROAD, HARTSHILL, ST4 7LG

EPC Report

Energy rating

Current: 64 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 57 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 76 Potential: 76
Field Value
LMK KEY 2070-2508-2423-2500-6541
ADDRESS1 228 QUEENS ROAD
ADDRESS2 HARTSHILL
ADDRESS3
POSTCODE ST4 7LG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-12-08
LOCAL AUTHORITY E06000021
CONSTITUENCY E14001520
COUNTY
LODGEMENT DATE 2020-12-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 258
ENERGY CONSUMPTION POTENTIAL 142
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 107
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 765
HEATING COST POTENTIAL 626
HOT WATER COST CURRENT 96
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 97
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.62
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 228 QUEENS ROAD, HARTSHILL
LOCAL AUTHORITY LABEL Stoke-on-Trent
CONSTITUENCY LABEL Stoke-on-Trent Central
POSTTOWN STOKE-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2020-12-08 16:51:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 3455079585
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000005
Address display
Nation ew