Energy Performance Certificate

99, Dukinfield Road, SK14 4PE

EPC Report

Energy rating

Current: 59 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 58 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 86 Potential: 86
Field Value
LMK KEY 2058-2008-7232-2304-1994
ADDRESS1 99, Dukinfield Road
ADDRESS2
ADDRESS3
POSTCODE SK14 4PE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-02-25
LOCAL AUTHORITY E08000008
CONSTITUENCY E14001515
COUNTY
LODGEMENT DATE 2014-02-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 245
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 796
HEATING COST POTENTIAL 480
HOT WATER COST CURRENT 100
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 99, Dukinfield Road
LOCAL AUTHORITY LABEL Tameside
CONSTITUENCY LABEL Stalybridge and Hyde
POSTTOWN HYDE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-02-25 23:17:46
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100011570746
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew