Energy Performance Certificate

9 Wedmore Road, UB6 8SB

EPC Report

Energy rating

Current: 82 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 83 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 83 Potential: 83
Field Value
LMK KEY 2050-9205-1070-2206-2121
ADDRESS1 9 Wedmore Road
ADDRESS2
ADDRESS3
POSTCODE UB6 8SB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2023-05-22
LOCAL AUTHORITY E09000009
CONSTITUENCY E14001208
COUNTY
LODGEMENT DATE 2023-05-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 100
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 226
HEATING COST POTENTIAL 226
HOT WATER COST CURRENT 80
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 78
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 0.97
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9 Wedmore Road
LOCAL AUTHORITY LABEL Ealing
CONSTITUENCY LABEL Ealing North
POSTTOWN GREENFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2023-05-23 06:54:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 12051226
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew