Energy Performance Certificate

38 Boyne Park, TN4 8ET

EPC Report

Energy rating

Current: 62 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 58 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 70 Potential: 70
Field Value
LMK KEY 2047-3052-0206-0645-1200
ADDRESS1 38 Boyne Park
ADDRESS2
ADDRESS3
POSTCODE TN4 8ET
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-06-24
LOCAL AUTHORITY E07000116
CONSTITUENCY E14001555
COUNTY
LODGEMENT DATE 2025-06-26
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 196
ENERGY CONSUMPTION POTENTIAL 139
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 11
LIGHTING COST CURRENT 166
LIGHTING COST POTENTIAL 167
HEATING COST CURRENT 5047
HEATING COST POTENTIAL 3608
HOT WATER COST CURRENT 228
HOT WATER COST POTENTIAL 228
TOTAL FLOOR AREA 483
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 34
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 14
NUMBER HEATED ROOMS 14
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial multiple glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.75
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38 Boyne Park
LOCAL AUTHORITY LABEL Tunbridge Wells
CONSTITUENCY LABEL Tunbridge Wells
POSTTOWN TUNBRIDGE WELLS
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2025-06-26 13:29:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 75
LOW ENERGY FIXED LIGHT COUNT 60
UPRN 100062585762
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew