Energy Performance Certificate

Flat 1, 62 Eastgate Street, GL1 1QN

EPC Report

Energy rating

Current: 69 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 70 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 80 Potential: 80
Field Value
LMK KEY 2044-3003-5209-3602-4200
ADDRESS1 Flat 1
ADDRESS2 62 Eastgate Street
ADDRESS3
POSTCODE GL1 1QN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2022-01-24
LOCAL AUTHORITY E07000081
CONSTITUENCY E14001248
COUNTY
LODGEMENT DATE 2022-01-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 260
ENERGY CONSUMPTION POTENTIAL 174
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 34
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 322
HEATING COST POTENTIAL 224
HOT WATER COST CURRENT 59
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 36
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.83
FLOOR HEIGHT 2.73
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1, 62 Eastgate Street
LOCAL AUTHORITY LABEL Gloucester
CONSTITUENCY LABEL Gloucester
POSTTOWN Gloucester
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-01-24 18:47:06
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 4
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew