Energy Performance Certificate

24 Sunningdale Drive, Warmley, BS30 8GP

EPC Report

Energy rating

Current: 70 C | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 69 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 84 Potential: 84
Field Value
LMK KEY 2040-5359-3020-3001-9071
ADDRESS1 24 Sunningdale Drive
ADDRESS2 Warmley
ADDRESS3
POSTCODE BS30 8GP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2022-01-31
LOCAL AUTHORITY E06000025
CONSTITUENCY E14001394
COUNTY
LODGEMENT DATE 2022-01-31
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 203
ENERGY CONSUMPTION POTENTIAL 81
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 413
HEATING COST POTENTIAL 388
HOT WATER COST CURRENT 60
HOT WATER COST POTENTIAL 37
TOTAL FLOOR AREA 65
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 87
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24 Sunningdale Drive, Warmley
LOCAL AUTHORITY LABEL South Gloucestershire
CONSTITUENCY LABEL North East Somerset and Hanham
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2022-01-31 12:58:21
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 543331
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew