Energy Performance Certificate

86 ISIS WAY, SANDHURST, GU47 9RB

EPC Report

Energy rating

Current: 36 F | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 36 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 88 Potential: 88
Field Value
LMK KEY 2039-0129-1000-0428-3296
ADDRESS1 86 ISIS WAY
ADDRESS2 SANDHURST
ADDRESS3
POSTCODE GU47 9RB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-01-18
LOCAL AUTHORITY E06000036
CONSTITUENCY E14001117
COUNTY
LODGEMENT DATE 2021-01-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 533
ENERGY CONSUMPTION POTENTIAL 70
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 90
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1057
HEATING COST POTENTIAL 325
HOT WATER COST CURRENT 286
HOT WATER COST POTENTIAL 63
TOTAL FLOOR AREA 55
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 86 ISIS WAY, SANDHURST
LOCAL AUTHORITY LABEL Bracknell Forest
CONSTITUENCY LABEL Bracknell
POSTTOWN SANDHURST
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2021-01-18 10:34:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100080218385
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew